fuhrmanOmegaWallFunctionFvPatchScalarField class
This boundary condition provides a wall function constraint on turbulnce specific dissipation, omega. The values are computed using:
\f[
\omega = sqrt(\omega_{vis}^2 + \omega_{log}^2)
\f]
where
| = | omega in viscous region | |
| = | omega in logarithmic region |
Model described by Eq.(15) of:
\verbatim
Menter, F., Esch, T.
"Elements of Industrial Heat Transfer Prediction"
16th Brazilian Congress of Mechanical Engineering (COBEM),
Nov. 2001